-40%

Elimia Air Compressor Pump Motor Starter 480V Coil 34-50 Amp Nema 4 30HP

$ 134.63

Availability: 55 in stock
  • Condition: New
  • Coil Voltage: 480V
  • Country/Region of Manufacture: United States
  • UL 508A listed: Yes
  • Input Voltage: 480V
  • MPN: ADD LED INDICATOR LIGHT
  • Model: ACMS 34-50-480N4
  • Enclosure Type: Enclosed Motor Starter
  • Overload Rating: 34-50 Amp
  • Nema Size: IEC SIZE 50
  • NEMA Rating: 4
  • HP Rating: 30HP @ 480V
  • Brand: Elimia

    Description

    Elimia ACMS Magnetic Motor Starter. Special enclosed starter set up for air compressors or pumps.
    UL 508A Certified
    Heavy duty steel Nema 4 enclosure with hinge door. Suitable for indoor or outdoor applications, water and dust proof.
    Nema 4X contols with A600 contact blocks.
    Every Motor Starter is built and tested to order in Alabama, USA.  Our customers come back time and time again, try one and you will see... Nothing else in this price range even comes close.
    We have updated our enclosed motor starters to make them better than ever. Now using Nema Rated LSis Motor Starter, made in Korea.
    Please note that the label on the pictured unit may be from a different rated unit.  Use the specifications below to verify for your application.
    Please call us if you have any questions. We want you to get the right equipment - 1-855-4Elimia.  We offer an extensive line of standard motor starters as well as custom built units.  Combination starters and reversing starters are also available in standard and custom configurations.
    Some models include a backlight switch on the enclosure door.  480V models DO NOT include an indicator light due to the extra cost for 480V LED.  We can add the backlight for an additional cost of .00.  The indicator light lets you know that the unit is ON and ready to run when the pressure switch closes. This is a nice feature to remind you to cut off the compressor at night so it doesn't cycle on/off all night.  Another feature we offer is a two pole circuit breaker to protect the control wiring going out to the pressure switch, we can add that for .00 also.  It is recommend that the circuit breaker or you add your own protection for 15HP and larger 480V air compressor motor starter we build.
    Pre-wired for easy installation.  Bring in power from the appropriate size breaker, run motor power from the starter box and extend the brown wires provided in the box to one set of contacts on your pressure switch.
    Model Number: ACMS 34-50-480N4
    Model Explanation:
    ACMS = Air compressor motor starter
    34-50  = Overload Size
    480 = Coil Voltage (suitable for 460-480V)
    N4 = Nema 4 steel enclosure
    Enclosure size is 10x8x4 inches
    Note that the picture shows
    Sized for 30 HP @ 480V 3 phase.  (Can be used on 25HP heavy load too)
    In our ongoing effort to provide high quality, low cost products with as little as possible Chinese content - this assembly contains very little China material. Here is the major content country of origin:
    Contactor - LSis Korea
    Overload - LSis Korea
    Enclosure - Taiwan
    Switch - Weg Brazil
    Indicator - Weg Brazil
    Assembly - Elimia United States Alabama
    Motor starters are made up of primarily two parts. A contactor and overload device. Both devices have maximum ratings and the overload has maximum and minimum ratings. You should choose a motor starter that fits both criteria. If you need help please email or call, we will be glad to assist.
    To size your starter properly you must determine the following:
    -Three phase or Single phase
    -Supply voltage ie. 120V; 208V; 230V; 460V; 600V
    -Machine single motor HP
    -Motor FLA (full load Amps) and worst case SFA (service factor Amps)
    -Application, what type of machine you running
    If your supply Voltage is 208V and you w
    ant
    to use your supply power to power the contactor coil...  Our 230V coils are rated down to 196 Volts.  Now, under most cases our standard 230V coil will work flawlessly on 208V systems.  But, if your machine is very large for your electrical service OR your wiring run is long or undersized I recommend using a separate 120V source for the coil power.
    Ratings of contactor used in this starter, do not exceed ratings:
    IEC Size 50 Contactor
    3 Phase 30HP at 480V
    You must use a control voltage
    460-480
    VAC
    for this unit, it is pre-wired to connect to your line connections on the starter.
    The control voltage is the voltage used to activate the coil of the contactor. In the simplest install you will want a coil voltage the same as your power supply. But is some cases you might want the control voltage to be different for a host of reasons.
    The overload will have an adjustable Amperage range. Your overload choice is based on your machines FLA. If your machine motor has a FLA of 10 Amps at your supply voltage then you should choose the overload where 10 Amp falls within the adjustable range. For a 10 Amp FLA we would recommend overload 9 - 13 Amps. Some folks size overloads based on FLA times the Service Factor. So, if your service factor is 1.15, your SFA is 1.15 x FLA. In the example above it equals 10 FLA X SFA = 11.5 Amps.
    Our overloads can be set for manual or automatic reset operation. The overload control is pre-wired by Elimia in a way that trips the starter. This is done to protect your equipment and is one of the main purposes of a motor starter.
    Components mounted on a easy to remove back plate.
    90 day replacement Elimia warranty.
    Great price!
    We have pre-wired motor starters available from 0 HP to 200 HP.
    Please call 1-855-4Elimia for more info or if we can help sizing a starter.
    Elimia has assembled and supplied thousands of starters to customers all over the world. In addition to our standard products we design and built custom control panels, VFDs, PLCs, container electrical systems, motor control centers etc... Our customers come back again and again for the value products we offer.
    Guarantee: Satisfaction Guaranteed! If you are not happy with your purchase within two weeks of arrival you can return it. No restocking fee! Offer excludes shipping and eBay fees. If the item has been installed and it turns out not be what you needed please call us. We will work with each customer and try to reach a resolution.
    There is no charge for on-sight pickup but 10% sales tax applies.
    Please note: All items should be professionally inspected and tested prior to installation or use. We are not liable for damages, injuries or death relating to our products.
    We reserve the right to refuse payment from buyers registered in foreign countries or locations with non corresponding ship to addresses. Additionally, we reserve the right to refuse payment from any buyer which will feel is acting in a possible malicious manner.
    Feedback: Once you are satisfied with your purchase please leave us feedback. If you have any problem with the transaction or product, please contact us.