-40%
Fluke T6-1000 Electrical Tester, 1000 V AC
$ 142.55
- Description
- Size Guide
Description
Untitled DocumentFluke T6-1000 Electrical Tester, 1000 V AC
Model:
T6-1000
| Order No:
T6-1000
Ideal for commercial and light industrial electricians, this tester measures voltage up to 1000 V AC through its open fork without any test lead contact to the live voltage. Additionally, this tool fits in your pocket and comes equipped with FieldSense technology, which detects an electrical field.
Brand:
Fluke
Model:
T6-1000
Order No:
T6-1000
Condition:
NEW
Description
Fluke T6-1000 Electrical Tester, 1000 V AC
Measure voltage … without test leads
Measure voltage up to 1000 V ac due to FieldSense technology, which easily and quickly takes measurements by sliding a conductor through the open fork. Additionally, without opening covers or removing wire nuts, on wires up to AWG 4/0 (120 mm2), carrying as much as 200 A which makes the jobs safer, faster and easier.
Features
FieldSense technology for ac voltage, current and frequency measurement without making electrical contact to live voltage
Simultaneous voltage and current display shows all power supply measurements at a glance for efficient troubleshooting
1 to 1000 V ac or dc
0.1 to 200 A ac
Resistance 1 &ohm to 100 k&ohm
Frequency measurement 45 to 66 Hz
Works with wires up to AWG 4/0 (120 mm2) with a 0.7" (17.8 mm) jaw opening
Hold button temporarily freezes the reading for easy viewing
Easy to read display with backlight
Why use this electrical tester?
Electricians often work in boxes jammed with wires, where finding a safe metallic contact point can be a challenge. With this tester they can take measurements by sliding a single wire into the open fork.
How FieldSense works
FieldSense technology is truly a breakthrough in how voltage is measured. While other open fork testers detect a magnetic field to show ac current, FieldSense technology detects an electrical field. This field interacts with a reference signal created by the tester, creating a voltage value on the tester's display.
Tips: FieldSense technology
Do not hold or touch wire you are testing during a measurement. Use the black probe to make the ground connection if:
Wearing gloves or insulated footwear
Standing on an insulated ladder
Additional ground contact is required for the application
FieldSense measurement looks like this when probably grounded:
Display color turns green
Display shows a valid measurement >16 V rather than dashes or 0.0
Shows for measurement ≥30 V
Applications
Commercial and light industry
elementExists('Blog/fluke-solving-electrical-problems-with-fluke-thermal-imaging')){echo $this->element('Blog/fluke-solving-electrical-problems-with-fluke-thermal-imaging'); }?>
Included
Electrical Tester
Attached Test Leads, with 0.16" (4 mm) Removable Probe Caps
User's Manual
Specifications
FieldSense AC Voltage True RMS
Requires Test Leads
No
Range
1000 V
Resolution
1 V
Accuracy
±(3% + 3 counts) 45 to 66 Hz
FieldSense AC Current True RMS
Requires Test Leads
No
Range
200.0 A
Resolution
0.1 A
Accuracy
±(3% + 3 counts) 45 to 66 Hz
FieldSense Frequency (Hz)
Requires Test Leads
No
Range
45 to 66 Hz
Resolution
1 Hz
Accuracy
±(1% + 2 counts)
Volts AC True RMS
Requires Test Leads
Yes
Range
1000 V
Resolution
1 V
Accuracy
±(1.5% + 2 counts) 45 to 66 Hz
Volts DC
Requires Test Leads
Yes
Range
1000 V
Resolution
1 V
Accuracy
±(1% + 2 counts)
Resistance
Requires Test Leads
Yes
Range
1000 V
2000 &ohm
20 k&ohm
100 k&ohm
Resolution
1 V
1 &ohm
0.01 k&ohm
0.1 k&ohm
Accuracy
±(1% + 2 counts)
Safety
Range
1000 V CAT III
600 V CAT IV
General Specifications
Calibration
One year calibration cycle
Jaw Opening
0.7" (17.8 mm)
Operating Temperature
14 to 122°F (-10 to 50°C)
Storage Temperature
-22 to 140°F (-30 to 60°C)
Operating Altitude
6562' (2000 m)
Storage Altitude
32,808' (10,000 m)
Relative Humidity
0 to 90%, 41 to 86°F (5 to 30°C)
0 to 75%, 86 to 104°F (30 to 40°C)
0 to 45%, 104 to 122°F (40 to 50°C)
Battery Type and Life
2 x AA (IEC LR6)
360 hours continuous
Typical; 200 hours using FieldSense
Temperature Coefficient
0.1 x (specified accuracy) /°C for <18 or >28°C
Safety
IEC/EN 61010-1: Pollution degree 2
Electromagnetic Environment
IEC/EN 61326-1: Portable
Dimensions
2.4 x 10.2 x 1.7" (61.1 x 259.3 x 43.8 mm)
Weight
0.78 lb (350 g)
Terms & Conditions
Item Condition:
Unless specified otherwise all products listed are Brand New in the original factory packaging and include a full factory warranty.
Shipping:
We currently only ship to U.S. buyers. We ship items within one or two business days from payment. We do not process shipments on weekends and holidays. Local pick up is not available. We only ship to addresses verifiable by either PayPal or credit card issuing bank.
Please note that we cannot alter the address once a purchase is made. In the case of PayPal payment, we will ship orders when the payment is marked “Eligible” for PayPal Seller’s protection.
*Shipping Rates are for Continental US, Please Contact us for other US Destinations
Payment:
Currently all payments must be made directly though PayPal
Sales Tax:
We are required to charge sales tax in North Carolina
Return Policy:
If for any reason you are not 100% satisfied with a product you receive from us, you may return the regular stock product within 30 days from the time of receipt, for a full refund or exchange of the product you purchased (less any shipping costs). Within this time, products may be returned; freight prepaid and must be in their original packaging and in resalable condition.
Shipping errors, missing items or damages must be reported to us immediately (damages should be accompanied by a signed bill of lading acknowledging the damage). Items returned will be inspected for damage or misuse at which time they may be subject to restocking fees, other fees or refused, prior to the issuance of any credit.