HP-410C, Hewlett Packard HP-410C, Overhauled

$ 264

Availability: 100 in stock
  • All returns accepted: ReturnsNotAccepted
  • MPN: Does Not Apply
  • Current Type: AC, DC, Ohms RF Voltage
  • Country/Region of Manufacture: United States
  • Display: Analog
  • Brand: HP
  • Condition: Refurbished
  • Frequency Range: NA

    Description

    **** For Auction
    ******** HP 410C VTVM ******
    *** Instrument Shown: HP 410C VTVM WITH HP RF PROBE ****
    *** Photos of unit for sale**
    HP 410C VTVM : INSTRUMENT OVERHAULED
    **** NOTE: This instrument has the "isolated mode & range switch shafts" ****
    * ALL CIRCUIT RESISTORS CHECKED, REPLACED AS NEEDED. RANGE RESISTORS CHECKED AT TIME OF INSTRUMENT CALIBRATION
    * HARDWARE ( MACHINE SCREWS ETC) REPLACED AS NEEDED AND MISSING HARDWARE REPLACED.
    * INTERNAL WIRING CHECKED AND REPLACED/REPAIRED AS NECESSARY
    * Interconnect wiring to A7 board has been hard wired, the original "slip on" connectors gone bye-bye.
    * A7 Board voltages checked.
    * Power supply voltages checked
    * AC Fine Zero panel control potentiometer disassembled, cleaned, lubricated and tested.
    * Knobs cleaned and clear-overcoated. Knob set screws lubricated.
    * Panel cleaned.
    * Components on AC (RF) probe jack replaced.
    * CAUTION "DO NOT ATTEMPT TO MEASURE LINE VOLTAGE" PLACARD INSTALLED
    * CASE NOT REPAINTED, THESE COVERS WERE ALMOST PRISTINE.
    * ORIGINAL CARRY HANDLE LEFT IN PLACE: NO RUST NOTED ( Very Unusual)
    * IEC AC CORD SET FURNISHED
    * METER MOVEMENT REPLACED
    * TEST LEAD ASSEMBLY REBUILT.
    AC (RF) probe nose piece is new
    AC (RF) probe ground clip is shop fabricated
    Test leads, alligator clips, all are new or rebuilt.
    New A3 & A7 boards installed and adjusted
    *ALL SWITCHES CLEANED AS NEEDED
    * UNIT CALIBRATED ( AC & DC & OHMS) USING A HP ANALOG VOLTMETER CALIBRATOR.
    *
    Calibration Note
    : Typically analog instrument calibration is done at the "top" (usually the right hand) of each scale. Intermediate calibration markings are "checked" but may or may not be accurate. The reason for this is the OEM calibrated each meter face individually for that particular SN instrument. Over time, the original tubes have been replaced, other components have been replaced, meter movements have been replaced, so the chances of the unit "calibration" being accurate at all portions of the scale of a particular instrument, are close to zero.
    * Shipping Via Fed Ex, Single Box, Well packaged, Insured for sale price. Double boxing available, email for cost.
    * All sales final, no warranties or guarantees expressed or implied, no returns or exchanges
    * Manual not furnished, manual copies : Bama (Edbris)
    * Photo: Unit for sale. Outside and inside.