    Vacuum Exposure Unit 110V
    ASC6050ZK Precise Vacuum UV Exposure Unit is equipped  with special UV lamps and auxiliary vacuum suction device. After putting  the screens and well printed transparency film on the glass, close its  cover and let it work after set the needed vacuum and exposure time,  then it will make the screens and transparency film close on the glass  tightly by evacuating the air of the vacuum charmer emerging from the  rubber blanket. When the set time is up, it will deflate automatically,  and then the exposure is finished. Please cut off the power supply.
    You could know more information by click the
    video link
    Working principle
    Screen printing screens are coated with a light sensitive emulsion using  a scoop coater. When the emulsion is dry, place your image with a  positive print on the screen. Once you burn the screen, the emulsion  that did not get any UV will wash out of the screen exposing the tiny  pin holes. The surrounding areas that were exposed to UV will be cured.  Hence the ink will pass through screen onto your substrate.
    Special Tips
    The vacuum pumping area (sizes of the rubber blanket) is 19.6”*23.6”  (50*60cm), (If your screen is oversized, please buy cautiously!)
    Operation Instructions
    1. Connect the power supply; Turn on the switch of “POWER”;
    2. Set the vacuum pumping time
    1) Press “VACUUM”, the left indicator light (yellow) is lit up;
    2)  Press “ + ” or “ – ” in the “TIME CONTROL” area to set the vacuum  pumping time according to your needs.
    (For first-time users, please put an empty screen in the middle of the  rubber inner cavity, just set 40 seconds for test; if the pointer of the  vacuum gauge could reach or pass the middle of the green area, that’s  ok. If not, please extend the time and test again until having reached  the requirement.
    3. Set the exposure time
    1)  Press “EXPOSURE”, the left indicator light (red) is lit up;
    2) Press “ + ” or “ – ” in the “TIME CONTROL” area to set the  exposure time according to your needs.
    (Exposure time varies according to the coated photosensitive emulsion.  Please just set 300 seconds for test and then reset a suitable time  according to the exposure effect.)
    4. Once finished the above settings, you could start exposure just as  follows
    1) Put the screens coated with  photosensitive emulsion and the printed transparency film on the  glass.
    2) Put the air suction pipe in to the screen;
    3) Close the cover and click the “START” button, then it will  vacuum pump and expose automatically according to the settings;
    4) When the set time is up, it will deflate automatically; Open  the cover and exposure is finished. Please just cut off the  power supply
    5. Functions of other keys
    1) “RESET” for canceling the  previous settings: if you want to reset the vacuum / exposure  time, just press “VACUUM” / “EXPOSURE” and the left indicator  light is lit up; Then press “RESET” and the original settings  will turn to “ 0 ”; Next, you could set according to your needs.
    2) “BACK” for stop working: if you want to stop vacuum pumping  or exposure, just press the “BACK” button, that’s ok.
    Breakdown Maintenance
    1. If the digit was not displayed once turned on the switch
    a. Please check whether the power supply is good or not
    b. Please check whether the bottom fuse wire is loose, burned-out or not
    2. If the vacuum pump didn’t work after putting the screen on the glass,  closing the cover and pressing the “STRAT” button:
    Please check whether the leading wire of the vacuum pump is well  connected or not
    3. If it didn’t reach the requirement even the vacuum pump works well
    a. please checks whether the air suction pipe is well fastened or not
    b. Please check whether the rubber blanket and its edgings were good and  seal or not.
    If there were some splits on the rubber blankets or edgings, or some  cracks of the edging adhesives, please fix them up with the sealing  adhesive.
    4. If the lamps were not lit up
    a. Please check whether your voltage was too low or not
    b. Please check whether the lamp ends were blackened or not caused by  lamp ageing
    c. Please check whether your set exposure time was 0 second
    d

    Please  check whether the ballast was broken or not.
    Notice
    1) Please cut off the power supply when you need to change the lamp or  the ballast
    2) Avoid contact with hard objects to prevent glass surface scratching
    3) Consistent cleaning is needed according to your using frequency and  operational environment, especially for the glass, vacuum rubber blanket  and edgings
    Essential  Parameters
    ·
    Input Voltage:
    110V
    ·
    Exposure area:
    15.6”*19.6” (40*50cm)
    ·
    Vacuum Degree:

    0.08Mpa
    ·
    Illumination Uniformity: 85%
    ·
    Lamp Power: 240W
    ·
    Vacuum Pump Power: 60W
    ·
    Vacuum Time Setting Range:  0-999s
    ·
    Exposure Time Setting Range:  0-999s
    ·
    Machine Size: 27.5”*27.5”*7”  (70*70*18cm)
    ·